China IGBT Fully Controlled Hydrogen Production Power Supply - Leading Suppliers and Factory Solutions
Product Features
Advanced phase-shifting full-bridge soft-switching control technology of power components is adopted to make the switch tube work in soft-switching state and reduce the loss of the switch tube. The switch tube of the inverter circuit of the transformer is a switch tube with low conduction voltage and low switching loss, and phase-shifting resonance control is adopted to realize soft switching.
The high-performance MOSFET tube has the advantages of high efficiency, simple structure, small on-state loss, strong current turn-off ability, fast switching speed, small loss and no secondary breakdown. There is almost no loss in the process of frequent turn-on and turn-off. The power saving is 10%. With the decrease of voltage and current, the proportion of energy saving will gradually increase.
Using high-frequency transformer, the volume is small, and the loss is generally less than 1%. The transformer loss is low. The loss of copper and iron in transformer is small. The circuit system features a reduced number of loss connection points, and the copper material is used. The power factor of high frequency power supply is high, and it is kept at 0.95.
Full-wave rectification technology is adopted to improve the efficiency of rectifier.
Strong isolation, strong anti-interference ability, and the harmonic is less than 5%
Distributed high-frequency power supply system works in parallel with power modules, and adopts system current sharing, N+M redundancy and hot plug technology, so that each converter can handle less power to reduce electrical stress, which breaks the bottleneck that the output power of a single converter is not large enough, and improves the output power to tens or even hundreds of kilowatts, greatly improving the reliability of the system.
Multi-Module Structure: High-power high-frequency power supply adopts multi-module parallel structure, with RS485 control system and current sharing system, and the current sharing coefficient is within 1%.
Soft Parallel Mode: Under normal circumstances, when one module fails, the system will automatically shut down the failed unit, and the other modules can still operate normally. The failed module can be hot-swapped and maintained, ensuring that power supply will never stop.
Electrical Parameters
| Output response time | ≤0.1s |
| Output ripple coefficient | ≤ 3% |
| Harmonic requirement | ≤3%~5% |
| Power factor | ≥0.94~0.99 |
| Conversion efficiency | ≥95%~97.5% |
| Power input range | 380V~690V±10% |
| Max output power | 6MW~9MW |
| Output voltage | 0~820 |
| Output current | 0~20000 |
| Output waveform | DC |
| Overload capacity | 110% |